Membrane nitrogen · Made in India for Saudi Arabia
Membrane nitrogen generator supplier for Jubail, Riyadh, Jeddah and Saudi Arabia
Gastek has built gas generation plants in India since 1993. Its membrane nitrogen generators make 95–99.5% nitrogen from compressed air, reach Saudi sites through Dammam, Jubail and Jeddah, and are sized for inland heat and dust, with export documents and commissioning support.
- Purity
- 95–99.5% nitrogen, dry; above 99.5%, PSA
- Capacity
- 1–5,000 Nm³/hr, modules in parallel
- Ambient
- Inland summer heat: modules sized for the hottest feed air the site sees
- Intake air
- Inland dust and sand: inlet filtration ahead of the compressor sized for it
- Humidity
- Humid Gulf and Red Sea air: compressor condensate drained before the modules
- Installation
- Skid in a ventilated utility room, under shade, or container-ready
- Ports
- King Abdulaziz Port, Dammam; Jubail Commercial Port; Jeddah Islamic Port; Yanbu Commercial Port
- Documents
- Invoice, packing list, certificate of origin, bill of lading, datasheets
- Electrical
- Electrical requirements are reviewed during sizing and quotation.
How a membrane nitrogen generator travels from India to a Saudi site
Road · sea · road
Greater Noida works
Engineering, assembly, testing and export packing.
By road
Mundra or Nhava Sheva
Export clearance and loading at a west-coast port.
Sea freight
Dammam or Jeddah
Import clearance by the consignee or their agent; Jubail and Yanbu also possible.
By road
Your site
Placement, hook-up and commissioning with Gastek's engineers, on site or remotely.
Exported
Nitrogen plants Gastek has exported
Membrane and PSA systems ship from the same Greater Noida works. These PSA plants are already running abroad; more are on the Projects page.
610Nm³/hr
Refinery project, Malta
CE-certified nitrogen package
1,100Nm³/hr
Polyester chip makers
PSA nitrogen plants in Egypt, Turkey and Thailand
15+
Export markets
Plants shipped from the Greater Noida works
Since 1993D-U-N-S 91-686-7372ISO 9001:2015
All plants Gastek has suppliedSite conditions
Saudi heat and dust, and where a membrane system meets them
A membrane's output shifts with the temperature of its feed air, and dust and oil are what wear the fibres. Inland sites see the most heat and dust; coastal sites the most humidity.
Regions
Membrane nitrogen generators in Jubail, Dammam, Riyadh and Jeddah
Each project is planned around the port route and the site's industrial city or area.
| Region | Port | Industrial cities and zones | Typical membrane duties |
|---|---|---|---|
| Jubail and Dammam | Jubail Commercial Port, King Abdulaziz Port, Dammam | Jubail, Dammam, Ras Al-Khair |
|
| Riyadh and Central Region | Route set per site | Riyadh industrial areas, Sudair, Al Kharj |
|
| Jeddah and Makkah Region | Jeddah Islamic Port | Western industrial zones |
|
| Yanbu and Red Sea | Yanbu Commercial Port | Yanbu Industrial City |
|
Applications
Membrane nitrogen for Saudi industries
Membrane fits where 95–99.5% holds the oxygen limit. Petrochemical process duties that need more go to PSA; the air supply, purity and flow decide.
Oil, gas and tank storage
Tank blanketing, line purging and inerting at terminals, storage sites and utilities, where a compact skid that starts with the air helps.
Oil and gas nitrogenChemical tank blanketing
Solvent and storage tanks in Jubail and Yanbu, blanketed and purged to each vessel's oxygen limit.
Chemical plant nitrogenFood packaging
Flushing packs of dates, snacks, dairy powders and coffee, and blanketing edible oils and juices, where 97–99.5% nitrogen holds the oxygen limit.
Food and beverage nitrogenMarine and offshore
Inerting and purging on vessels, offshore units and in Gulf and Red Sea yards, where a compact skid with no adsorbent beds suits the space.
Membrane nitrogen for marineTyre service and fire prevention
Dry nitrogen for tyre inflation in fleet and aviation service, and oxygen-reduction systems for archives and stores.
Membrane generator detailsHigher purity: PSA
Refinery and petrochemical process duties, laser cutting and pharma usually need more than 99.5%. Gastek supplies PSA nitrogen generators to Saudi Arabia for those.
PSA nitrogen in Saudi Arabia
Enquiry to start-up
From enquiry to start-up at a Saudi site
Built for plant, procurement and project teams who need a clear supplier quotation before approval or a purchase order.
01
Requirement review
Flow, purity, outlet pressure, application, operating hours, the Saudi site location, the compressed air available and the hottest site temperature are checked before sizing.
02
Engineering and quotation
Membrane modules, filtration, compressor scope, receiver, controls and layout are defined, with the air flow the system needs at your purity.
03
Manufacture and testing
Built at the Greater Noida works, assembled, tested and prepared for inspection and export packing.
04
Export documents
Commercial invoice, packing list, certificate of origin, bill of lading support, datasheets and drawings.
05
Shipping to Saudi Arabia
Sea freight to Dammam, Jubail, Jeddah or Yanbu, chosen by site and consignee, then road to site.
06
Start-up
Commissioning, purity check, operator guidance, filter-change planning and spares, timed to site readiness.
Saudi buyer questions
Saudi membrane nitrogen generator questions
Can Gastek supply a membrane nitrogen generator to Saudi Arabia?
Yes. Gastek builds membrane nitrogen generators in India and supports Saudi buyers in Jubail, Dammam, Riyadh, Jeddah and Yanbu with sizing, the quotation, export documents, shipping, commissioning and spares.
Does Saudi heat affect a membrane nitrogen generator?
Yes, and the design allows for it. A membrane's nitrogen output and purity change with the temperature of its feed air, and inland summers push that temperature up. Gastek sizes the modules for the hottest air the compressor will deliver on site, and places the skid in a ventilated room or under shade.
Membrane or PSA nitrogen for a Saudi site?
Membrane suits 95–99.5% duties where a compact skid that starts with the air matters: tank blanketing, line purging, food packaging, marine and tyre service. PSA suits higher purity, up to 99.999%, and large continuous flows such as refinery and petrochemical process duties. Gastek supplies both to Saudi Arabia and quotes the one that fits the duty.
Which ports and regions does Gastek ship to?
Systems ship to King Abdulaziz Port in Dammam or Jubail Commercial Port for the Eastern Province, to Jeddah Islamic Port for the west, and to Yanbu for the Red Sea industrial city. Riyadh and central sites are reached by road from Dammam.
What does a membrane nitrogen generator cost in Saudi Arabia?
The price follows the duty: nitrogen flow, purity, pressure, the compressed air supply and filtration. For a Saudi project it also depends on the delivery terms, ex-works, FOB or delivered to Dammam, and on the import duty and VAT paid at the Saudi end. Send the duty and Gastek quotes a configured system with its running cost.
Can it run on our existing compressor?
Possibly. The compressor needs enough spare flow and pressure at the required air quality, on the hottest day, after its other users are served. Gastek reviews the air supply when sizing, and adds filtration or a dedicated compressor where the existing one falls short.
How long does it take from order to start-up?
Manufacture and testing come first, then sea freight, then clearance, installation and commissioning. Gastek confirms the schedule with the quotation, because it depends on the size and scope of the system.
What information is needed for a quotation?
Nitrogen flow and peak, purity or residual oxygen, outlet pressure, application, operating hours, the city and site, the compressed air available, the hottest ambient temperature, and any document requirements.
Saudi quotation
Send the Saudi requirement. Gastek sizes the system around it.
Flow, purity, pressure, the air you have and the city are enough to start. Gastek replies with a configured membrane system, the air it needs, and the shipping route.
Gastek contact hoursMon–Sat, 9:00 am–6:00 pm IST
- Nitrogen flow, and the peak
- Purity, or the oxygen limit at the use point
- Outlet pressure and operating hours
- Your compressed air: spare flow, pressure and quality
- City and site and the hottest ambient temperature